Skip to main content

Heart rate variability tests for diagnosing cardiovascular autonomic neuropathy in patients with type 2 diabetes mellitus in advanced stages of kidney disease

Abstract

Cardiovascular Autonomic Neuropathy (CAN) is one of the most devastating complications of Diabetes Mellitus (DM) and presents high morbidity and mortality. Its association with diabetic kidney disease (DKD) worsens the condition even further. CAN diagnosis remains a challenge and is being based on reflex tests which are laborious, risky and difficult to perform. Heart Rate Variability (HRV) tests has been suggested as having high utility in diagnosing CAN, but this issue remains controversial. The aim is to evaluate the sensitivity and specificity of HRV tests to diagnose CAN in patients with type 2 diabetes mellitus (T2DM) and DKD with severely increased albuminuria. This is a cross-sectional study in patients with T2DM and DKD with severely increased albuminuria. A total of 48 subjects were recruited and underwent laboratory and neuropathy assessment. The diagnosis of CAN was first confirmed in 75% (36/48) of patients based on cardiovascular autonomic reflex tests (CARTs). HRV tests (VLF, LF, TP and SDNN) differed between groups with and without CAN (212 vs. 522 ms2, p = 0.024; 57 vs. 332 ms2, p = 0.025; 359.5 vs. 2733 ms2, p = 0.007; 20 vs. 48 ms, p = 0.012), respectively. The best cut-off points based on ROC curve were < 1,117 ms2, < 152.5 ms2, < 1,891 ms2 and < 46.5 ms, respectively. VLF and TP reached highest sensitivity values (97% and 92%) and F1 Score of 90%, while LF had best specificity (75%) and TP had best accuracy (85%). Our best model of serial algorithm using VLF as first screening test and TP in sequency obtained a sensitivity of 97% and accuracy of 90%, reducing in 90% the need to perform CARTs. Our findings suggest that it is possible to achieve high sensitivity and accuracy using an algorithm with VLF and TP parameters analyzed in series. It could enable a simpler and early diagnosis, avoiding CARTs complications.

Background

Cardiovascular autonomic neuropathy (CAN) is one of diabetes neuropathies, which represents the most prevalent, underdiagnosed and undertreated diabetes complication [1]. CAN is a degenerative condition that affects 16.7-34.3% patients with diabetes mellitus (DM), with a multifactorial pathogenesis, related to diabetes duration, poor glycemic control and, more recently, with hypertension [2,3,4].

CAN early diagnosis is a key factor to manage this condition and slowing its progression is associated with better quality of life and prognosis [5]. The signs and symptoms of autonomic neuropathy should be carefully investigated, as they generally appear in late stages and are usually represented by a non-specific clinic, such as tachycardia, gastroparesis, constipation, diarrhea, erectile dysfunction [6].

The gold standard for diagnosis is cardiovascular autonomic reflex tests (CARTs), which assess autonomic function through provocative maneuvers (lying to standing, deep breathing and Valsalva maneuver) that analyze heart rate and blood pressure [7]. CARTs may expose patients to risks related to increasing of intrathoracic, intraocular, and intracranial pressure and may theoretically be associated with a small risk of intraocular hemorrhage or lens dislocation [8]. These complications could have their frequency increased in more debilitated patients with the presence of other complications associated with diabetes, especially diabetic kidney disease (DKD).

DKD is a chronic microvascular complication of DM that affects up to 40% of patients with DM2, and is the leading cause of chronic kidney disease worldwide [9,10,11,12]. It has been suggested that DRD contributes significantly to the onset and progression of cardiovascular disease (CVD), through pathophysiological mechanisms such as hypertension, dyslipidemia and endothelial dysfunction, leading to outcomes such as myocardial hypertrophy, acute myocardial infarction and heart failure [13].

In summary, CAN is one of the most devastating complications of DM and presents high morbidity and mortality and could be a useful marker for progression of diabetes complications, especially DKD [7, 14,15,16]. Its association with DKD worsens the condition even further [2, 15,16,17,18,19,20,21,22]. CAN diagnosis remains a challenge and is being based on reflex tests which are laborious and difficult to perform. Recently, time and frequency domain tests has been suggested as having high utility in diagnosing CAN, but this issue is still controversial [23, 24]. In this context, this study aims to evaluate the sensitivity and specificity of time and frequency domain diagnostic tests, to enable a simpler and early diagnosis, avoiding CARTs complications, which could lead to swifter appropriate therapy and avoid poor outcomes for these patients.

Materials and methods

Study design and pacients

This is a cross-sectional study to evaluate sensitivity and specificity of frequency and time domain tests for CAN diagnostic in patients with diabetes mellitus type 2 (T2DM) and DKD with severely increased albuminuria. A total of 51 subjects with T2DM and DKD were recruited from the Federal University of Pará - Brazil endocrinology department from 2023 to 2024. CAN diagnosis was established according to Toronto consensus (gold standard based on cardiovascular autonomic reflex tests) [7].

It was developed according to the Declaration of Helsinki and the Nuremberg Code and was approved by the University Hospital João de Barros Barreto ethics committee, reference number 88974918.6.0000.0017. Informed Consent Form (ICF) was obtained from all patients.

Inclusion criteria consisted in: (a) providing consent through the ICF obtained prior to any study procedure; (b) patients with type 2 DM aged over 30 years with regular follow-up with an endocrinologist; (c) treatment with oral hypoglycemic agents or insulin at a stable dose for at least three months; (d) patients with DKD and severely elevated albuminuria (> 300 mg/g); (e) patients taking any anti-hypertensive medication must be on a stable dose during 4 weeks prior to study; (f) ability and willingness to perform all study procedures; (g) eGFR > 25 and < 90mL/min/1.73 m². Exclusion criteria were (a) patient with type 1 diabetes; (b) hypothyroidism or decompensated hyperthyroidism; (c) pregnant women or women intending to become pregnant or breastfeeding; (d) patients with alcohol abuse or taking recreational drugs that, in the opinion of the researcher, would put the patient’s safety and the study procedures at risk; (e) patients with clinically significant arrhythmias that could interfere in CARTs execution.

Data collection

After eligibility criteria evaluation, qualified individuals were started on the study procedures. All patients had a well-established clinical and laboratory diagnosis of T2DM [25]. CAN evaluation was always made in the morning, with fasting capillary glycemia levels between 70 and 250 mg/dl. Subjects were instructed not to use alcohol, caffeine beverages and tobacco for at least 8 h before the test, and not to perform vigorous physical exercises 24 h before examination.

Parameters used to diagnose CAN were deep breathing test, Valsalva coefficient, lying to standing test (30/15 coefficient and systolic blood pressure (SBP) reduction in orthostasis). Subjects were considered not to have CAN when presenting up to 1 abnormal parameter. The presence of two abnormal parameters was defined as criteria to diagnose definitive CAN [7]. Severe CAN was reported when patients presented orthostatic hypotension.

Patients underwent blood and urine sample collection. HbA1c was analyzed using the HPLC method [26]. Creatinine was analyzed using the kinetic/automated method and the CKD-EPI 2021 equation was used to calculate GFR [27]. The patients underwent albuminuria measurement in an isolated sample by evaluating 3 urine samples isolated on different days, analyzed using the immunoturbidimetry method [24].

Can evaluation

The CARTs used were deep breathing, Valsalva and lying to standing (30:15 coefficient and orthostasis) [28, 29]. Diagnosis was established according to Toronto consensus [7] only based on CARTs results (gold standard). During CAN evaluation, heart rate variability (HRV) and time parameters were also measured with the patient resting in supine position.

The VNS-MICRO software (Neurosoft, Ivanovo, Russia) was used to analyze data [30, 31]. The test begins with patients in supine positions and an electrocardiographic record for 300 s was performed. R waves are highlighted by the software and each regular RR interval is analyzed by a math algorithm and then expressed through an amplitude diagram of heart rate oscillation (HR fluctuations per second) versus heart rate (HR) in hertz. Total amplitude of HRV spectrum is distributed in three bands: (1) Very Low Frequency (VLF) component (0.01 to 0.04 Hz), which is related to vasomotor tonus (sympathetic control); (2) Low Frequency (LF) component (0.4 to 0.15 Hz), associated with baroreceptor reflex; and (3) High Frequency (HF) component (0.15 to 0.5 Hz), related to parasympathetic control (vagus nerve). These represent frequency domain parameters, which also include Total Power (TP), a set of three combined spectral bands and LF/HF ratio, which reflects balance between sympathetic and parasympathetic systems.

Besides those items, software provided time domain parameters. RRmin (minimum RR interval), RRmax (maximum RR interval); RRNN (mean length of regular RR intervals); and SDNN (standard deviation of all NN intervals).

As no extended analysis of all HRV and time parameters in large normal populations has been performed, reference values described by Angelink et al. 200130 were based on studies involving few patients. Therefore, values should have been considered as approximate, and no definite clinical decisions should be based on them.

Statistical analysis

Data collected was organized and analyzed using SigmaStat 3.5® (Jandel Scientific Corporation, Chicago, Illinois) and Statistical Package for Social Sciences (SPSS 22®). The analysis was carried out according to the distribution values (considering normality by the Shapiro-Wilk test p > 0.05) and for the null hypothesis rejected a p < 0.05 in all tests. For variables with a normal distribution, the Student’s t-test for two independent samples and ANOVA repeated measures were used. For variables with a non-normal distribution, the Mann-Whitney U test was used for independent samples and the Kruskal Wallis test for more than two samples. For categorical variables, the chi-square or Fisher test was used, with data reported as absolute values and frequency (%). For variables with a normal distribution, data are reported as mean ± standard deviation; for non-normal distribution, data are reported as median (quartile 25–75). For sensitivity, specificity, accuracy, prevalence, positive predictive value (PPV) and negative predictive value (NPV), the standard formulas were used, and cross-analysis of the paired tests was carried out to obtain the joint sensitivity and specificity. The best cut-off point was defined based on Youden Index (J) and, additionally, a ROC (Receiver Operating Characteristic) curve was constructed. The cut-off with maximum sensitivity and specificity in the ROC curve was defined as the minimum value in the equation √ [(1– sensitivity)2 + (1– specificity)2] and the accuracy was estimated based on the area under the ROC curve. Predictive values and likelihood ratios were also calculated from the values of sensitivity and specificity. Sensitivity, specificity and diagnostic accuracy were expressed as percentage.

Our sample size was calculated based on an expected power of 0.8 to detect the difference between the most used HRV parameter (VLF) in patients with and without CAN. The number of patients necessary was 45 cases, with an expected difference in median equals to 600 ms2, an expected standard deviation of 1000 and an alpha of 0.05. Since this group was composed by 48 patients, the power of our study to identify difference between those variables was > 0.8 and considered satisfactory.

Results

A total of 51 patients with DM2 and DRD were recruited, but three patients were excluded because they were unable to undergo reflex tests. A total of 48 subjects underwent diagnostic tests for CAN, and 36 (75%) had a confirmed diagnosis of CAN. As expected, those patients presented long-term diabetes, associated to a higher frequency of complications (Table 1).

Table 1 Clinical and laboratorial parameters of patients with DM2 and DRD with severely increased albuminuria

The comparison of autonomic neuropathy tests (CARTs, HRV and time domain parameters) in patients with and without CAN are shown in Table 2. The parameters (HRV and time domains) that showed significant differences between groups (TP, VLF, LF and SDNN) were subsequently evaluated as tests for the diagnosis of CAN.

Table 2 Test parameters for patients with and without a diagnosis of CAN

Figure 1 shows data from ROC curves analysis with HRV and time domain parameters. Based on Youden Index (J), optimal cut-off points to diagnosing CAN for TP, LF, VLF and SDNN were < 1891 ms2, < 152,5 ms2, < 1117 ms2 and < 46,5 ms, respectively

Fig. 1
figure 1

Cut-off points for HRV parameters on the diagnosis of can based on ROC curve. AUC: Area under the ROC curve; 95% IC: confidence interval; J: Youden Index; Sens: Sensitivity; Spec: Specificity; Accu: Accuracy; LR+: Positive Likelihood Ratio; LR -: Negative likelihood ratio; TP = Total power. VLF = Very low frequency; LF = Low frequency; SDNN = Standard deviation from normal RR intervals.

A summary of HRV and time parameters individual diagnostic performance is shown on Table 3. In addition, matching these tests in parallel has not improved the results.

Table 3 Sensitivity, specificity, accuracy, and positive and negative predictive values for cut-offs of CAN parameters

In addition, we have tested a few models of serial and sequential algorithms using HRV and time domain parameter to diagnose CAN and trying to avoid performing CARTs. Our best model used VLF as first screening test and TP in sequence. This algorithm presented a sensitivity of 97%, specificity of 67%, accuracy of 90%, with positive and negative likelihood ratios of 2.93 and 0.04. We achieved these results using CARTs in only 10% of the sample, enabling a fast-screening procedure and avoiding CARTs adverse events in 90% of patients.

At the end of the model, 39/48 (81%) patients had abnormal tests results, 35 True Positives (33 identified by abnormal VLF + TP and 2 by CARTs) and 4 False Positives. Among 9/48 (19%) normal results, there was 1 False Negative and 8 healthy individuals, 5 of these identified at the screening by normal VLF and 3 by CARTs (Fig. 2).

Fig. 2
figure 2

Can diagnostic algorithm in patients with T2DM and advanced stages DKD. T2DM: Type 2 diabetes mellitus; DKD: Diabetic kidney disease; EKG: electrocardiogram; VLF = Very low Frequency; TP = Total Power; CAN: Cardiovascular autonomic neuropathy.

Discussion

Our study was the first to evaluate the diagnostic performance of HRV and time parameters for CAN in patients with long-standing T2DM and advanced DKD, with severely increased albuminuria. Our findings suggest that it is possible to achieve high sensitivity and accuracy using an algorithm with the VLF and TP parameters analyzed in series. This algorithm achieved a sensitivity of 97%, specificity of 67%, accuracy of 90%, with positive and negative likelihood ratios of 2.93 and 0.04. In our serial model, the need to perform CARTs, initially used in all patients (N = 48), would be reduced to 10% of individuals. These procedures would enable a fast-screening process and avoid CARTs adverse events in 90% of patients. This would be an important advance, considering a fragile population with several comorbidities and risks associated to its realization. Additionally, when evaluated individually the HRV and time parameters (VLF, LF, TP and SDNN), showed also to be useful to diagnose CAN, presenting sensitivity of 97%, 75%, 92% and 89%, and specificity of 42%, 75%, 67% and 67% respectively, in this population.

Ewing’s cardiovascular autonomic reflex testing (CART), the actual gold standard for diagnosing CAN [7], is a fully established tool and a powerful marker of cardiovascular prognosis, with good sensitivity (93% to deep-breathing and lying-to-standing, and 98% to Valsalva), specificity (100% if three abnormal tests and 98% if two abnormal tests) [32] and reproducibility (coefficients of variation: 9.2, 12.6, and 6.4% for the Valsalva, deep-breathing, and lying-to-standing tests, respectively) [7, 33,34,35]. However it is widely used, these tests are difficult to perform, due to its laborious procedures, and have some limitations in clinical practice, especially in fragile populations. For example, mobility challenges or the presence of Charcot osteoarthropathy are cited as difficulties to perform lying-to-standing test [36]; evaluating postural hypotension is not reliable for patients with fluid retention, something to be considered in a DKD population [37], and severe arrythmias figure as a contraindication [2]. As consequence, they are not routinely realized, leading to CAN underdiagnosis. The Valsalva Maneuver increases intrathoracic, intraocular and intracranial pressures and may be associated with an increased risk of retinal hemorrhages, which is why it is recommended to avoid it in patients with proliferative retinopathy [7]. In addition, in individuals with T2DM and CAN, exercise tolerance is significantly reduced because of poor physical conditions that compromise their aerobic capacity [38], and when associated with DKD, this condition is worsened [39]. As a result, it is important to find alternatives to simplify screening process and avoid clinical complications of CARTs, reducing exposure to tests that patients may not be able to perform.

HRV and time parameters analysis, based on electrocardiographic short-term measurements (5, 10–20 min) [40, 41], is an easy-to-use, non-invasive technique with good reproducibility [42, 43], as well as efficiently assessing sympathetic and parasympathetic activity [42,43,44]. As no comprehensive investigations of all HRV indices in large normal populations have yet been performed, normalized values were obtained from studies involving small number of subjects [45]. The values should therefore have been considered as approximate, and no definite clinical conclusions should be based on them. Therefore, studies in many subgroups of patients need to be performed to establish reliable thresholds [45].

Several studies have demonstrated the applicability of HRV and time parameters [46,47,48,49,50,51]. Tang et al. used Bayesian models to determine normality values for time and frequency parameters, which showed sensitivity and specificity of over 80%, and the results were comparable to Ewing’s diagnostic battery [23]. A Spanish study that compared CARTs and the heart rate variability power spectrum (HRV-PS) found that the LF parameter was the best for diagnosing NAC [52]. In our study, TP was the well-balanced parameter to be used alone to diagnose CAN in this population. The Atherosclerosis Risk in Communities (ARIC) Study, which followed more than 13,000 patients over 16 years, concluded that low heart rate variability was associated with the development of severe renal outcomes, such as hospitalizations for renal failure, dialysis and death from acute renal failure in patients with previous chronic disease [53]. Recently, the study by Min et al. tried to identify the behavior of HRV in patients with end stage renal disease, a population in which CAN is quite prevalent, and all the time and frequency parameters were altered, in the groups with or without DM [54]. Both articles show that the association of CAN and ESRD (end-stage renal disease) leads to poor outcomes, and that the assessment of time and frequency domain parameters is useful to screening CAN earlier and mitigate complications. In addition, some studies have demonstrated that patients with Non Albuminuric DKD also have increased cardiovascular risk. Therefore, albuminuria should always be evaluated in parallel with e-GFR in those patients [15]. Finally, HRV parameters have been linked to a higher cardiovascular risk, especially with lipid and glucose markers [55] and it has been associated to several cardiovascular biomarkers, such as genetic, inflammatory and cardiac performance [56]. Nevertheless, in this study, our main objective was to identify a screening method that could avoid or even replace cardiovascular autonomic neuropathy reflex tests to diagnose CAN. Our serial model could diagnose CAN and avoid performing CARTs in 90% of this population. It could be meaningful for managing this relevant diabetes complications which remain underdiagnosed. We did not evaluate the correlation between HRV parameters and other cardiovascular risk biomarkers.

There are many current softwares for HRV analysis, each with its strengths and limitations, and choosing one of these tools may depend mostly on specific research needs and the user’s familiarity with the software environment. Specially for diagnosing CAN, most studies rely on diagnostic accuracy of HRV parameters using softwares with linear algorithms [57, 58], such as time (SDNN, SDANN, pNN50, ecc) and frequency domains (VLF, LF, HF, HF/LF ratio). The first is based on statistical calculations of consecutive RR intervals and the last on indexes based on spectral analysis [59]. In our study, VNS Micro by Neurosoft was used for HRV data acquisition, an easy to carry and read tool, offering rhythmograms, spectrograms, measurement tables, and automatic interpretation according to the International standard [23]. Kubios HRV is known for its comprehensive analysis capabilities relying not only on linear analysis, providing also nonlinear HRV parameters, not affected by nonstationarity, as it happens for linear indexes [59] and shows the ability to correct artifacts and remove trends enhances the accuracy of HRV measurements [57, 58]. HRVanalysis provides advanced time-frequency analysis using wavelet transform, more nuanced understanding of HRV changes over short periods, which is essential for early detection of CAN [60]. Recently, The SCN4ALL Pulse Rate Variability Analysis Module has been validated against Kubios HRV, which provides validated PRV indices similar to HRV, figuring as an alternative for HRV analysis for remote monitoring of autonomic function, extremely useful in telemedicine scenario [61].

The main limitations of our study were a small sample and few patients without CAN (control group). We are studying individuals with long standing T2DM and severely increased albuminuria, which leads to a high CAN prevalence [62] and increased difficulties to recruit patients in a control group [63]. Our most sensitive parameter (VLF) also showed low specificity. But we compensated this issue proposing a serial algorithm model that reached higher values. Additionally, HRV and time parameters have some confounder factors, for example DKD patients are known to have increased sympathetic nerve activity [64, 65], therefore we cannot determinate whether HRV and time parameters alterations are due to renal impairment or to CAN itself.

As we are aware, this is the first study to propose a diagnosis algorithm in patients with T2DM and severely increased albuminuria, reaching high sensitivity in a risky group for developing CAN.

Conclusion

This study proposes the possibility of using HRV parameters to diagnose CAN in patients with T2DM and severely increased albuminuria. A serial algorithm was created using VLF and TP parameters, obtaining high sensitivity and accuracy, and reducing 90% the need to perform CARTs. Further studies with a larger population are needed to confirm our findings.

Data availability

The datasets analyzed during the current study are available from the corresponding author on reasonable request.

Abbreviations

ACEI:

Angiotensin converting enzyme inhibitors

ARB:

Angiotensin receptor blocker

ARIC:

Atherosclerosis risk in communities

CAN:

Cardiovascular autonomic neuropathy

CARTS:

Cardiovascular reflex tests

CKD-EPI:

Chronic kidney disease epidemiology collaboration

CVD:

Cardiovascular disease

DKD:

Diabetes kidney disease

DM:

Diabetes mellitus

eGFR:

Glomerular filtration rate

ESRD:

End Stage Renal Disease

HbA1c:

Glycated hemoglobin

HF:

High Frequency

HPLC:

High-performance liquid chromatography

HR:

Heart rate

HRV:

Heart rate variability

HRV-PS:

Heart rate variability power spectrum

ICF:

Informed consent form

LF:

Low frequency

NPV:

Negative predictive value

PPV:

Positive predictive value

ROC:

Receiver operating characteristic

RRmax:

Maximum RR interval

RRmin:

Minimum RR interval

RRNN:

Mean length of regular RR intervals

SBP:

Systolic blood pressure

SDNN:

standard deviation of all NN intervals

SPSS:

Statistical Package for Social Sciences

T2DM:

Type 2 diabetes mellitus

TP:

Total power

VLF:

Very low frequency

References

  1. Rolim LC, Thyssen PJ, Flumignan RL, Andrade DCD, Dib SA, Bertoluci M. Diagnóstico e Tratamento Da neuropatia periférica diabética. Diretriz Oficial Da Sociedade Brasileira De Diabetes. 2022. https://doiorg.publicaciones.saludcastillayleon.es/10.29327/557753.2022-14.

    Article  Google Scholar 

  2. Vinik AI, Maser RE, Mitchell BD, Freeman R. Diabetic autonomic neuropathy. Diabetes Care. 2003;26:1553–79.

    Article  PubMed  Google Scholar 

  3. Freeman R. Diabetic autonomic neuropathy. Handbook of clinical neurology. Elsevier; 2014. pp. 63–79.

  4. American Diabetes Association Professional Practice Committee. 12. Retinopathy, neuropathy, and foot care: standards of care in diabetes-2024. Diabetes Care. 2024;47:S231–43.

    Article  Google Scholar 

  5. Rolim LCDSP, Sá JRD, Chacra AR, Dib SA. Neuropatia autonômica cardiovascular diabética: fatores de Risco, impacto clínico e Diagnóstico precoce. Arq Bras Cardiol. 2008. https://doiorg.publicaciones.saludcastillayleon.es/10.1590/S0066-782X2008000400014.

    Article  PubMed  Google Scholar 

  6. ElSayed NA, Aleppo G, Aroda VR, et al. Introduction and methodology: standards of care in diabetes—2023. Diabetes Care. 2023;46:S1–4.

    Article  PubMed  Google Scholar 

  7. Spallone V, Ziegler D, Freeman R, et al. Cardiovascular autonomic neuropathy in diabetes: clinical impact, assessment, diagnosis, and management. Diabetes Metabolism Res. 2011;27:639–53.

    Article  Google Scholar 

  8. Therapeutics and Technology Assessment Subcommittee of the American Academy of Neurology. Assessment: clinical autonomic testing report of the therapeutics and technology assessment subcommittee of the American academy of neurology. Neurology. 1996;46:873–80.

    Google Scholar 

  9. Tuttle KR, Bakris GL, Bilous RW, et al. Diabetic kidney disease: a report from an Ada consensus conference. Diabetes Care. 2014;37:2864–83.

    Article  PubMed  PubMed Central  Google Scholar 

  10. Stevens PE. Evaluation and management of chronic kidney disease: synopsis of the kidney disease: improving global outcomes 2012 clinical practice guideline. Ann Intern Med. 2013;158:825.

    Article  PubMed  Google Scholar 

  11. De Boer IH, for the DCCT/EDIC Research Group. Kidney disease and related findings in the diabetes control and complications trial/epidemiology of diabetes interventions and complications study. Diabetes Care. 2014;37:24–30.

    Article  PubMed  Google Scholar 

  12. Samsu N. (2021) Diabetic nephropathy: challenges in pathogenesis, diagnosis, and treatment. BioMed Research International 2021:1497449.

  13. Afkarian M, Sachs MC, Kestenbaum B, Hirsch IB, Tuttle KR, Himmelfarb J, De Boer IH. Kidney disease and increased mortality risk in type 2 diabetes. J Am Soc Nephrol. 2013;24:302–8.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  14. Pop-Busui R. Cardiac autonomic neuropathy in diabetes. Diabetes Care. 2010;33:434–41.

    Article  PubMed  PubMed Central  Google Scholar 

  15. Cho I, Lim S, Kwon M, Chung SM, Moon JS, Yoon JS, Won KC. Cardiovascular autonomic neuropathy and the risk of diabetic kidney disease. Front Endocrinol (Lausanne). 2024;15:1462610.

    Article  PubMed  Google Scholar 

  16. Eun Jun J, Sun Choi M, Hyeon Kim J. Cardiovascular autonomic neuropathy and incident diabetic kidney disease in patients with type 2 diabetes. Diabetes Res Clin Pract. 2022;184:109181.

    Article  PubMed  Google Scholar 

  17. Ang L, Dillon B, Mizokami-Stout K, Pop-Busui R. Cardiovascular autonomic neuropathy: A silent killer with long reach. Auton Neurosci. 2020;225:102646.

    Article  PubMed  Google Scholar 

  18. Eleftheriadou A, Spallone V, Tahrani AA, Alam U. Cardiovascular autonomic neuropathy in diabetes: an update with a focus on management. Diabetologia. 2024;67:2611–25.

    Article  PubMed  PubMed Central  Google Scholar 

  19. Tang Y, Ang L, Jaiswal M, et al. Cardiovascular autonomic neuropathy and risk of kidney function decline in type 1 and type 2 diabetes: findings from the Perl and accord cohorts. Diabetes. 2024;73:751–62.

    Article  CAS  PubMed  Google Scholar 

  20. Spallone V. Blood pressure variability and autonomic dysfunction. Curr Diab Rep. 2018;18:137.

    Article  PubMed  Google Scholar 

  21. Bhati P, Moiz JA, Naqvi IH, Hussain ME. Diagnostic performance of resting and post-exercise heart rate variability for detecting cardiac autonomic neuropathy in type 2 diabetes mellitus. Auton Neurosci. 2019;219:53–65.

    Article  PubMed  Google Scholar 

  22. Wheelock KM, Jaiswal M, Martin CL, et al. Cardiovascular autonomic neuropathy associates with nephropathy lesions in American Indians with type 2 diabetes. J Diabetes Complicat. 2016;30:873–9.

    Article  Google Scholar 

  23. Tang Z-H, Wang L, Zeng F, Li Z, Yu X, Zhang K, Zhou L. Bayesian Estimation of cardiovascular autonomic neuropathy diagnostic test based on short-term heart rate variability without a gold standard. BMJ Open. 2014;4:e005096.

    Article  PubMed  PubMed Central  Google Scholar 

  24. Castiglioni P, Faini A, Nys A, De Busser R, Scherrenberg M, Baldussu E, Parati G, Dendale P. Heart rate variability for the early detection of cardiac autonomic dysfunction in type 1 diabetes. Front Physiol. 2022;13:937701.

    Article  PubMed  PubMed Central  Google Scholar 

  25. American Diabetes Association Professional Practice Committee. 2 Diagnosis and classification of diabetes: standards of care in diabetes-2024. Diabetes Care. 2024;47:S20–42.

    Article  Google Scholar 

  26. Netto AP. A1C e O controle glicêmico: Um Desafio Para Todos. J Bras Patol Med Lab. 2009. https://doiorg.publicaciones.saludcastillayleon.es/10.1590/S1676-24442009000100002.

    Article  Google Scholar 

  27. Miller WG, Kaufman HW, Levey AS, et al. National kidney foundation laboratory engagement working group recommendations for implementing the ckd-epi 2021 race-free equations for estimated glomerular filtration rate: practical guidance for clinical laboratories. Clin Chem. 2022;68:511–20.

    Article  PubMed  Google Scholar 

  28. Ewing DJ. Assessment of cardiovascular effects in diabetic autonomic neuropathy and prognostic implications. Ann Intern Med. 1980;92:308.

    Article  CAS  PubMed  Google Scholar 

  29. American Diabetes Association. Standards of medical care in diabetes—2008. Diabetes Care. 2008;31:S12–54.

    Article  Google Scholar 

  30. Agelink MW, Malessa R, Baumann B, Majewski T, Akila F, Zeit T, Ziegler D. Standardized tests of heart rate variability: normal ranges obtained from 309 healthy humans, and effects of age, gender, and heart rate. Clin Auton Res. 2001;11:99–108.

    Article  CAS  PubMed  Google Scholar 

  31. Vns-micro - neuropathy analyzing system. https://neurosoft.com/en/catalog/hrv-analysis/VNS-micro. Accessed 9 Jan 2025.

  32. Ziegler D, Dannehl K, Mühlen H, Spüler M, Gries FA. Prevalence of cardiovascular autonomic dysfunction assessed by spectral analysis, vector analysis, and standard tests of heart rate variation and blood pressure responses at various stages of diabetic neuropathy. Diabet Med. 1992;9:806–14.

    Article  CAS  PubMed  Google Scholar 

  33. Valensi P, Attali J, Gagant S, French Group for Research and Study of Diabetic Neuropathy. Reproducibility of parameters for assessment of diabetic neuropathy. Diabet Med. 1993;10:933–9.

    Article  CAS  PubMed  Google Scholar 

  34. Bellavere F, Ragazzi E, Chilelli NC, Lapolla A, Bax G. Autonomic testing: which value for each cardiovascular test? An observational study. Acta Diabetol. 2019;56:39–43.

    Article  PubMed  Google Scholar 

  35. Tannus LRM, Sperandei S, Montenegro Júnior RM, et al. Reproducibility of methods used for the assessment of autonomous nervous system’s function. Auton Neurosci. 2013;177:275–9.

    Article  PubMed  Google Scholar 

  36. Pafili K, Trypsianis G, Papazoglou D, Maltezos E, Papanas N. Simplified diagnosis of cardiovascular autonomic neuropathy in type 2 diabetes using Ewing’s battery. Rev Diabet Stud. 2015;12:213–9.

    Article  PubMed  PubMed Central  Google Scholar 

  37. Campbell IW, Ewing DJ, Clarke BF. Therapeutic experience with fludrocortisone in diabetic postural hypotension. Br Med J. 1976;1:872–4.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  38. Han B-G, Lee JY, Kim MR, Shin H, Kim J-S, Yang J-W, Kim JY. Fluid overload is a determinant for cardiac structural and functional impairments in type 2 diabetes mellitus and chronic kidney disease stage 5 not undergoing dialysis. PLoS ONE. 2020;15:e0235640.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  39. Lav Madsen P, Sejersen C, Nyberg M, Sørensen MH, Hellsten Y, Gaede P, Bojer AS. The cardiovascular changes underlying a low cardiac output with exercise in patients with type 2 diabetes mellitus. Front Physiol. 2024;15:1294369.

    Article  PubMed  PubMed Central  Google Scholar 

  40. Shaffer F, Meehan ZM, Zerr CL. A critical review of ultra-short-term heart rate variability norms research. Front Neurosci. 2020;14:594880.

    Article  PubMed  PubMed Central  Google Scholar 

  41. John APP, Udupa K, Avangapur S, Sujan MU, Inbaraj G, Vasuki PP, Mahadevan A, Anilkumar R, Shekar MA, Sathyaprabha TN. Cardiac autonomic dysfunctions in type 2 diabetes mellitus: an investigative study with heart rate variability measures. Am J Cardiovasc Dis. 2022;12:224–32.

    PubMed  PubMed Central  Google Scholar 

  42. Huang W, Hwang B, Lai C, Li J, Kuo TBJ, Yang CCH. Is heart rate variability related to season of birth?? Clin Cardiol. 2015;38:407–12.

    Article  PubMed  PubMed Central  Google Scholar 

  43. Sinnreich R, Kark J, Friedlander Y, Sapoznikov D, Luria M. Five minute recordings of heart rate variability for population studies: repeatability and age-sex characteristics. Heart. 1998;80:156–62.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  44. Chou Y, Huang W, Chang C, Yang CCH, Kuo TBJ, Lin S, Chiang W, Chu T. Heart rate variability as a predictor of rapid renal function deterioration in chronic kidney disease patients. Nephrology. 2019;24:806–13.

    Article  CAS  PubMed  Google Scholar 

  45. Electrophysiology TFOTESOCTNA. Heart rate variability: standards of measurement, physiological interpretation, and clinical use. Circulation. 1996;93:1043–65.

    Article  Google Scholar 

  46. Pop-Busui R, Backlund JC, Bebu I, Braffett BH, Lorenzi G, White NH, Lachin JM, Soliman EZ, DCCT/EDIC Research Group. Utility of using electrocardiogram measures of heart rate variability as a measure of cardiovascular autonomic neuropathy in type 1 diabetes patients. J Diabetes Invest. 2022;13:125–33.

    Article  CAS  Google Scholar 

  47. Benichou T, Pereira B, Mermillod M, Tauveron I, Pfabigan D, Maqdasy S, Dutheil F. Heart rate variability in type 2 diabetes mellitus: A systematic review and meta–analysis. PLoS ONE. 2018;13:e0195166.

    Article  PubMed  PubMed Central  Google Scholar 

  48. Sacre JW, Jellis CL, Coombes JS, Marwick TH. Diagnostic accuracy of heart-rate recovery after exercise in the assessment of diabetic cardiac autonomic neuropathy. Diabet Med. 2012. https://doiorg.publicaciones.saludcastillayleon.es/10.1111/j.1464-5491.2012.03719.x.

    Article  PubMed  Google Scholar 

  49. Phurpa M, Ferdousi S. Short-term heart rate variability: a technique to detect subclinical cardiac autonomic neuropathy in type 2 diabetes mellitus. Mymensingh Med J. 2021;30:447–52.

    CAS  PubMed  Google Scholar 

  50. Silva L, de SD NNM, de Melo FTC, et al. Improvement in cardiovascular autonomic neuropathy after high-dose vitamin d supplementation in patients with type 1 diabetes. Front Endocrinol (Lausanne). 2020;11:605681.

    Article  PubMed  Google Scholar 

  51. Felício JS, Santos FM, de Souza ACC, Felício KM, Ribeiro AB, Zanella MT. Autonomic neuropathy tests correlate with left ventricular mass and cardiac diastolic function in normotensive patients with type 2 diabetes mellitus and without left ventricular hypertrophy. Exp Clin Cardiol. 2010;15:e5–9.

    PubMed  PubMed Central  Google Scholar 

  52. Cabezas-Cerrato J, Gonzalez-Quintela A, Perez-Rodriguez M, Calle A, Faure-Noguera E, Vazquez-Garcia JA. Combination of cardiorespiratory reflex parameters and heart rate variability power spectrum analysis for early diagnosis of diabetic cardiac autonomic neuropathy. Diabetes Metab. 2009;35:305–11.

    Article  CAS  PubMed  Google Scholar 

  53. Brotman DJ, Bash LD, Qayyum R, Crews D, Whitsel EA, Astor BC, Coresh J. Heart rate variability predicts Esrd and ckd-related hospitalization. J Am Soc Nephrol. 2010;21:1560–70.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  54. Min JW, Chang J-Y, Lee H, Park Y, Ko EJ, Cho JH, Yang CW, Chung BH. Clinical significance of heart rate variability for the monitoring of cardiac autonomic neuropathy in end-stage renal disease patients. Nutr Metabolism Cardiovasc Dis. 2021;31:2089–98.

    Article  CAS  Google Scholar 

  55. Plaza-Florido A, Sacha J, Alcantara JMA. Associations between different heart rate variability ratios and cardiometabolic risk factors in young adults. Am J Hum Biol. 2022;34:e23797.

    Article  CAS  PubMed  Google Scholar 

  56. Papaioannou V, Pneumatikos I, Maglaveras N. Association of heart rate variability and inflammatory response in patients with cardiovascular diseases: current strengths and limitations. Front Physiol. 2013. https://doiorg.publicaciones.saludcastillayleon.es/10.3389/fphys.2013.00174.

    Article  PubMed  PubMed Central  Google Scholar 

  57. Lin K, Wei L, Huang Z, Zeng Q. Combination of ewing test, heart rate variability, and heart rate turbulence analysis for early diagnosis of diabetic cardiac autonomic neuropathy. Medicine. 2017;96:e8296.

    Article  PubMed  PubMed Central  Google Scholar 

  58. Zhang Z, Ma Y, Fu L, Li L, Liu J, Peng H, Jiang H. Combination of composite autonomic symptom score 31 and heart rate variability for diagnosis of cardiovascular autonomic neuropathy in people with type 2 diabetes. J Diabetes Res. 2020;2020:1–8.

    CAS  Google Scholar 

  59. Francesco B, Maria Grazia B, Emanuele G, Valentina F, Sara C, Chiara F, Riccardo M, Francesco F. (2012) Linear and nonlinear heart rate variability indexes in clinical practice. Comput Math Methods Med 2012:219080.

  60. Khandoker AH, Jelinek HF, Palaniswami M. Identifying diabetic patients with cardiac autonomic neuropathy by heart rate complexity analysis. BioMed Eng OnLine. 2009;8:3.

    Article  PubMed  PubMed Central  Google Scholar 

  61. Antali F, Kulin D, Lucz KI, Szabó B, Szűcs L, Kulin S, Miklós Z. Multimodal assessment of the pulse rate variability analysis module of a photoplethysmography-based telemedicine system. Sensors. 2021;21:5544.

    Article  PubMed  PubMed Central  Google Scholar 

  62. Ko S-H, Park S-A, Cho J-H, et al. Progression of cardiovascular autonomic dysfunction in patients with type 2 diabetes. Diabetes Care. 2008;31:1832–6.

    Article  PubMed  PubMed Central  Google Scholar 

  63. Lai Y-C, Li H-Y, Jiang Y-D, Chang T-J, Chuang L-M. Decreased glomerular filtration rate and increased albuminuria for identification of cardiovascular autonomic neuropathy in subjects with and without diabetes. Auton Neurosci. 2021;230:102757.

    Article  PubMed  Google Scholar 

  64. Liu M. Non-dipping is a potent predictor of cardiovascular mortality and is associated with autonomic dysfunction in haemodialysis patients. Nephrol Dialysis Transplantation. 2003;18:563–9.

    Article  Google Scholar 

  65. Sabino-Carvalho JL, Mekonnen E, Zanuzzi M, Li S, Cui X, Park J. Impaired neurocirculatory control in chronic kidney disease: new evidence for blunted sympathetic baroreflex and reduced sympathetic transduction. Function. 2024;5:zqae036.

    Article  PubMed  PubMed Central  Google Scholar 

Download references

Acknowledgements

The authors of the paper thank all the colleagues who contributed to this study and the patients who willingly participated in the study.

Funding

No funding was received for conducting this study.

Author information

Authors and Affiliations

Authors

Contributions

All persons who meet authorship criteria are listed as authors, and all authors certify that they have participated sufficiently in the work to take public responsibility for the content, including participation in the concept, design, analysis, writing, or revision of the manuscript. J.S.F, M.A.M.A., G.N.L., P.A.B.F., L.S.D.S., took part in conception and design of study. I.J.F., E.G.C., A.R.B.M., C.F.N., G.M.A.P. and V.S.G.L. were responsible for acquisition of data, while G.N.L., M.A.M.A., and L.O.R. have done the analysis and interpretation of data. N.N.M.Q., F.T.M., K.M.F., A.C.C.B.S., P.P.F.P., M.C.S., J.S.F. have drafted the manuscript together. All authors have revised the manuscript critically and approved the version to be published.

Corresponding author

Correspondence to João Soares Felício.

Ethics declarations

Ethics approval and consent to participate

The studies involving human participants were reviewed and approved by University Hospital João de Barros Barreto ethics committee, in accordance with the national legislation, resolution 466/12 (National Health Council). A written informed consent form to participate in this study was obtained from all patients.

Consent for publication

Not applicable.

Competing interests

The authors declare no competing interests.

Additional information

Publisher’s note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Open Access This article is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License, which permits any non-commercial use, sharing, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if you modified the licensed material. You do not have permission under this licence to share adapted material derived from this article or parts of it. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by-nc-nd/4.0/.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Felício, J.S., Araújo, M.A.M., de Lemos, G.N. et al. Heart rate variability tests for diagnosing cardiovascular autonomic neuropathy in patients with type 2 diabetes mellitus in advanced stages of kidney disease. Cardiovasc Diabetol 24, 144 (2025). https://doiorg.publicaciones.saludcastillayleon.es/10.1186/s12933-025-02666-z

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doiorg.publicaciones.saludcastillayleon.es/10.1186/s12933-025-02666-z

Keywords